Inter-observer error for each acquisition protocol (mean ± s.d.). |
|||||
| EDV |
ESV |
SV |
EF |
LV mass |
|
| (ml) |
(ml) |
(ml) |
(%) |
(g) |
|
|
|
|||||
| Standard |
-1.0 ± 7.2 |
-1.0 ± 5.5 |
0.0 ± 6.7 |
0.4 ± 3.2 |
3.9 ± 8.2 |
| Accelerated |
3.3 ± 5.0 |
2.3 ± 4.8 |
1.0 ± 5.8 |
-0.7 ± 3.5 |
3.8 ± 9.0 |